PowerSight Images Library
Click on an image to view it at its maximum resolution.
|
Click to Enlarge
|
Voltage and Current Logs All PowerSight models are excellent tools for logging voltage, current, and power parameters. Log graphs of RMS values can be displayed on your PC with PSM software (supplied with every PowerSight) and pasted into a Word document with a mouse click. Note that PSM allows you to zoom, expand, export to Excel and annotate with labels to highlight events or behavior. |
|
Click to Enlarge
|
Power and Energy Studies All PowerSight models measure and record power (watts, VA, VAR, PF) and energy in KWh. Going green? PowerSight meters are ideal for energy audits, or verification of energy savings measures. See a completed power study report here: Report and a "before and after" comparison report here: Comparison Report |
|
Click to Enlarge
|
View real-time waveforms, harmonics, phasors in scope mode The oscilloscope features in all PowerSight meters allow you to view voltage and current waveforms, see the harmonic spectrum on any phase and get phasor diagrams. |
|
Click to Enlarge
|
Set triggers for power quality events, (sags, swells, transients), current inrush etc. The PowerSight models PS4000 and PS4500 allow you to program triggers in the voltage and current domains to catch voltage sags and swells, transients (impulses) to 8us, or current inrush events when large machines or motors start up. |
|
Click to Enlarge
|
Harmonic Spectra All PpowerSight meters measure harmonics to the 50th harmonic. (Note: For the PS250 and PS2500 loggers harmonics measurement is an option - option model # HAO) PS250 |
|
Click to Enlarge
|
Harmonic table of magnitudes and phase angles All PowerSight meters measure harmonics to the 50th harmonic and can display both the harmonic spectra for voltage or current, and a harmonic magnitude and phase angle table. (Note: For the PS250 and PS2500 loggers harmonics measurement is an option - option model # HAO) PS250 |
|
Click to Enlarge
|
Phasors View phasor diagrams with any PowerSight model. Check connections and imbalance. Observe on a PC or PDA safely away from high voltages using Bluetooth communications with Bluetooth-enabled PowerSight meters. |
|
Click to Enlarge
|
Transient Transient voltage recorded by PS4000/PS4500 Power Quality Analyzer. PSM software allows you to zoom further, annotate and print. |
|
Click to Enlarge
|
PowerSight in SCAS2 case Thanks go to Bruce Lonie of PowerCet (a consulting and training company) who sent us this excellent picture of a PowerSight monitoring power to large walk-in food coolers in a commercial kitchen. He cleverly used the soft case SCAS2 to hang the meter out of harms way, and in a safe way. More information on the SCAS2 is here: SCAS2 PowerCet can be contacted at: www.powercet.com |
|
Click to Enlarge
|
Power Quality: Voltage Sag or Dip event Example of a voltage sag or dip captured by PowerSight PS4500 Power Quality Analyzer. Sags less than 10 cycles in duration are presented in a sinusoidal format. Sags longer than 10 cycles are presented in the RMS domain. |
|
Click to Enlarge
|
Power Quality: RMS Voltage Sag or Dip event Example of a voltage sag or dip captured by PowerSight PS4500 Power Quality Analyzer. Sags less than 10 cycles in duration are presented in a sinusoidal format. Sags longer than 10 cycles are presented in the RMS domain. This is an example of a voltage sag caused by a large load (such as a motor) turning on, running for a few seconds, then turning off. |
|
Click to Enlarge
|
Power Quality: Sub-cycle Transient or Impulse Capture The PowerSight PS4500 Power Quality Analyzer captures high-speed or sub-cycle transients (sometimes referred to as spikes or impulses) down to 8us and up to 1000V peak. |
|
Click to Enlarge
|
The Solution to NFPA 70E / CSA Z462 Working Challenges Be Comfortable. Be Safe. With PowerSight meters from Summit Technology, Inc. PowerSight meters / analyzers with Bluetooth wireless communications allow you to: Remove protective gear in a safe area and get away from high voltages after installing probes. Remotely perform power monitoring and electrical testing (up to 25 feet away) via a PC or PDA Read this technical paper:Electrical Testing Safety Application Note |
|
Click to Enlarge
|
Total Harmonic Distortion log This graph shows THD (Total Harmonic Distortion) logged over time for both voltage and current. PowerSight models PS4000/PS4500 measure to 63rd order as standard. PS3000/PS3500 measure harmonics to 50th order as standard. PS250/PS2500 measure harmonics to 50th order as an option, (HAO option). |