HA5 - 5 Amp High Accuracy Current Probe
Features
Designed to monitor permanently mounted CTs (Current Transformers), the range of 20 milliamps to 5 amps gives the best resolution and accuracy for measurement circuits and step-down transformers.
The range from 20 milliamps to 5 amps is a great choice for accurate high-resolution monitoring of small 3 phase loads. [NOTE: For high accuracy non-intrusive testing of single phase loads, use the 120ADP accessory, for high accuracy of very small loads (down to 2 milliamps) use the HA-GFD].
The compact size of the HA5 allows it to be used in very confined spaces.
The light weight and special measurement range of the HA5 makes it a great choice for a second set of current measurement probes for your analyzer.
Specifications
Measurement Range:
20 milliamps to 5 Amps AC
Accuracy/Linearity:
+/- 1% of reading +/- 0.002 amps over measurement range
Frequency Response:
+/- 1% from 50Hz to 3000Hz
Dimensions:
Inside diameter: 0.8 inch diameter
Outside dimensions: 5.25 x 2.1 x 1.35 inches
Cable length: 2 meters (6 feet).
Voltage Rating:
600V CAT III
Power Requirements:
no external power required